Passive Fire Protection Specialists · Auckland & Hamilton

Priced off the drawings. Signed off without drama.

Fireblock helps builders, mechanical contractors and facility managers deliver fully tested, certified passive fire protection for commercial, industrial and high-density residential developments. Complete passive fire work faster — with compliant installations, PS3-ready documentation and specialist fire-rated duct expertise.

*Free site visits available for commercial projects within our Auckland & Hamilton service areas — conditions apply.

Fire Stopping Fire-Rated Ducts Compliance Remedial Works

NZBC C1–C6 · NZBC G4 · AS 1668.1 / 1668.2 · AS 1530.4 Tested Systems

About Fireblock

One crew. Every layer of passive fire.

At Fireblock, we help protect buildings from the spread of fire, smoke and heat through proven passive fire protection systems.

We work with project managers, quantity surveyors, main contractors, engineers and facility managers — and we speak your language. Our background is in construction estimating, so quantities are taken off the drawings, scope boundaries are defined before we price, and variations don't appear out of nowhere.

From new construction to remedial works, our experienced team delivers accurate, professional and practical fire stopping solutions.

Auckland & Hamilton
Local crews, rapid response
10-Year Warranty
Fully backed workmanship guarantee
End-to-End Scope
Specification, installation & remediation
100% PS3-Ready
Digital tracking & photo-documented handovers
Our Services

Four services. One contractor.

Fireblock covers the full passive fire scope — so project managers deal with one crew, not three.

01

Fire Stopping

Professional installation of tested fire stopping systems to maintain fire compartmentation.

  • Penetration sealing
  • Pipe penetrations
  • Cable penetrations
  • Service penetrations
  • Fire collars
  • Fire pillows & wraps
  • Fire rated sealants
02

Fire Rated Duct Protection

Specialist fire protection so duct systems maintain required fire resistance performance.

  • Kitchen exhaust ducts
  • Mechanical ductwork
  • Smoke control systems
  • Fire rated enclosures
03

Passive Fire Compliance

Helping projects achieve and prove compliance, start to finish.

  • Site inspections
  • Defect identification
  • Remedial fire stopping
  • Documentation support
  • Compliance reporting
04

Remedial Passive Fire Works

Existing buildings often require upgrades — we sort it without disrupting operations.

  • Fire stopping repairs
  • Non-compliant penetrations
  • Damage rectification
  • Building maintenance requirements
// Systems We Install

Six installs that hold the line when everything else fails.

01 // Rated Ductwork

Fire-Rated Ducts

Board and wrap systems that keep the airway intact and the fire outside — rated to the FRR your fire report specifies.

STAYS COOL
02 // Intumescent Collar

Fire Collars & Wraps

Intumescent collars that expand under heat, crushing combustible pipes shut and sealing the penetration.

CRUSHED SHUT ✓
03 // Penetration Seals

Firestopping

Every service penetration through a rated wall or slab is a breach point. Tested seal systems restore the separation.

SEALED ✓
04 // Reactive Coating

Intumescent Coatings

Reactive coatings that expand up to 50× under heat, insulating structural steel and preserving load capacity.

EXPANDS ~50×INSULATES STEEL
05 // Damper Blades

Fire & Smoke Dampers

Fusible-link dampers that close automatically at temperature, maintaining separation where ductwork crosses fire cells.

SHUT TIGHT ✓
06 // Cavity Barrier

Cavity Barriers

Barriers that block concealed cavity paths — one of the most common routes for undetected fire spread.

FIRE STOPPED ↑
Spotlight

Kitchen exhaust ducts — the last line of defence.

One example of what "fire rated duct protection" means in practice.

-/120/120FRR MINUTES
For Commercial Kitchens · Cafés · Restaurants · Takeaways

When the grease catches, your duct is the last line of defence.

A grease fire travels up the exhaust riser in seconds. A fire-rated duct is the one thing standing between a kitchen flare-up and building-wide fire spread — and under the New Zealand Building Code, it's a requirement, not an option.

Where a kitchen exhaust riser passes through a fire separation, the Building Code requires it to maintain that separation for the rated period. No rating, no sign-off.

NZBC C1–C6 NZBC G4 AS 1668.1 / 1668.2 AS 1530.4 Tested
Why Choose Fireblock

Compliance-focused, start to finish.

✓

Tested & Appraised Systems Only

We strictly install systems verified under AS 1530.4 and AS 4072.1, sourced from leading premium manufacturers.

✓

Experienced Specialists

Passive fire is all we do — not a sideline to another trade.

✓

Auckland & Hamilton Coverage

Local crews across both regions, not a call centre.

✓

Tested, Approved Systems

We install systems from Ryanfire, Trafalgar, Firestop Centre, Protecta, Promat and BOSS — matched to your fire report, never substituted without sign-off.

✓

Compliance-Focused Approach

Every job scoped and documented against the standard it needs to meet.

✓

Fast Response Times

Quotes turned around quickly so your programme doesn't stall.

✓

Commercial & Residential

From landmark fit-outs to single-unit remedial jobs.

✓

Clear Documentation

Photo reports, marked-up drawings and compliance certificates, every time.

✓

10-Year Workmanship Warranty

We stand behind every join and every collar we fit.

Installing tested systems from: Ryanfire · Trafalgar · Firestop Centre · Protecta · Promat · BOSS

We Support

Every building type, one standard of work.

Commercial Buildings Apartments Industrial Facilities Retail Developments Hospitals & Care Facilities Mechanical Contractors Construction Projects
Proven On

Landmark fit-outs.

Hospitality

Qantas Lounge

Auckland

Passive fire protection and duct fire-rating through a live commercial fitout.

Civic & Cultural

Waikato Regional Theatre

Hamilton

Fire stopping and duct fire-rating across a large-scale civic construction programme.

Retail

Sylvia Park

Auckland

Fire-rated extract ductwork and penetration sealing for a major retail environment.

Our Process

Simple, documented, no surprises.

1

Site Assessment

We inspect requirements and identify passive fire needs.

2

Solution

We recommend suitable tested systems.

3

Installation

Our team completes works professionally.

4

Documentation & Handover

PS3 Producer Statements, marked-up drawings, product data sheets, installation schedule and QA documentation — everything your compliance schedule and CCC require, in one handover.

Request A Quote

Need passive fire
protection? Let's talk.

Send through your fire report and drawings for a measured price, or book a free site visit* for commercial projects across Auckland & Hamilton. Drawings can be attached by email — we price off the documents, not a guess.

Address9 Hereford Lane, Drury, Auckland 2579
Service AreaAuckland & Hamilton

*Free site visits available for commercial projects within our Auckland & Hamilton service areas — conditions apply. Have documents ready? Email your fire report and drawings to chandra@fireblock.co.nz and we'll price off them directly.