Priced off the drawings. Signed off without drama.
Fireblock helps builders, mechanical contractors and facility managers deliver fully tested, certified passive fire protection for commercial, industrial and high-density residential developments. Complete passive fire work faster — with compliant installations, PS3-ready documentation and specialist fire-rated duct expertise.
*Free site visits available for commercial projects within our Auckland & Hamilton service areas — conditions apply.
NZBC C1–C6 · NZBC G4 · AS 1668.1 / 1668.2 · AS 1530.4 Tested Systems
One crew. Every layer of passive fire.
At Fireblock, we help protect buildings from the spread of fire, smoke and heat through proven passive fire protection systems.
We work with project managers, quantity surveyors, main contractors, engineers and facility managers — and we speak your language. Our background is in construction estimating, so quantities are taken off the drawings, scope boundaries are defined before we price, and variations don't appear out of nowhere.
From new construction to remedial works, our experienced team delivers accurate, professional and practical fire stopping solutions.
Four services. One contractor.
Fireblock covers the full passive fire scope — so project managers deal with one crew, not three.
Fire Stopping
Professional installation of tested fire stopping systems to maintain fire compartmentation.
- Penetration sealing
- Pipe penetrations
- Cable penetrations
- Service penetrations
- Fire collars
- Fire pillows & wraps
- Fire rated sealants
Fire Rated Duct Protection
Specialist fire protection so duct systems maintain required fire resistance performance.
- Kitchen exhaust ducts
- Mechanical ductwork
- Smoke control systems
- Fire rated enclosures
Passive Fire Compliance
Helping projects achieve and prove compliance, start to finish.
- Site inspections
- Defect identification
- Remedial fire stopping
- Documentation support
- Compliance reporting
Remedial Passive Fire Works
Existing buildings often require upgrades — we sort it without disrupting operations.
- Fire stopping repairs
- Non-compliant penetrations
- Damage rectification
- Building maintenance requirements
Six installs that hold the line when everything else fails.
Fire-Rated Ducts
Board and wrap systems that keep the airway intact and the fire outside — rated to the FRR your fire report specifies.
Fire Collars & Wraps
Intumescent collars that expand under heat, crushing combustible pipes shut and sealing the penetration.
Firestopping
Every service penetration through a rated wall or slab is a breach point. Tested seal systems restore the separation.
Intumescent Coatings
Reactive coatings that expand up to 50× under heat, insulating structural steel and preserving load capacity.
Fire & Smoke Dampers
Fusible-link dampers that close automatically at temperature, maintaining separation where ductwork crosses fire cells.
Cavity Barriers
Barriers that block concealed cavity paths — one of the most common routes for undetected fire spread.
Kitchen exhaust ducts — the last line of defence.
One example of what "fire rated duct protection" means in practice.
When the grease catches, your duct is the last line of defence.
A grease fire travels up the exhaust riser in seconds. A fire-rated duct is the one thing standing between a kitchen flare-up and building-wide fire spread — and under the New Zealand Building Code, it's a requirement, not an option.
Where a kitchen exhaust riser passes through a fire separation, the Building Code requires it to maintain that separation for the rated period. No rating, no sign-off.
Compliance-focused, start to finish.
Tested & Appraised Systems Only
We strictly install systems verified under AS 1530.4 and AS 4072.1, sourced from leading premium manufacturers.
Experienced Specialists
Passive fire is all we do — not a sideline to another trade.
Auckland & Hamilton Coverage
Local crews across both regions, not a call centre.
Tested, Approved Systems
We install systems from Ryanfire, Trafalgar, Firestop Centre, Protecta, Promat and BOSS — matched to your fire report, never substituted without sign-off.
Compliance-Focused Approach
Every job scoped and documented against the standard it needs to meet.
Fast Response Times
Quotes turned around quickly so your programme doesn't stall.
Commercial & Residential
From landmark fit-outs to single-unit remedial jobs.
Clear Documentation
Photo reports, marked-up drawings and compliance certificates, every time.
10-Year Workmanship Warranty
We stand behind every join and every collar we fit.
Installing tested systems from: Ryanfire · Trafalgar · Firestop Centre · Protecta · Promat · BOSS
Every building type, one standard of work.
Landmark fit-outs.
Qantas Lounge
Passive fire protection and duct fire-rating through a live commercial fitout.
Waikato Regional Theatre
Fire stopping and duct fire-rating across a large-scale civic construction programme.
Sylvia Park
Fire-rated extract ductwork and penetration sealing for a major retail environment.
Simple, documented, no surprises.
Site Assessment
We inspect requirements and identify passive fire needs.
Solution
We recommend suitable tested systems.
Installation
Our team completes works professionally.
Documentation & Handover
PS3 Producer Statements, marked-up drawings, product data sheets, installation schedule and QA documentation — everything your compliance schedule and CCC require, in one handover.
Need passive fire
protection? Let's talk.
Send through your fire report and drawings for a measured price, or book a free site visit* for commercial projects across Auckland & Hamilton. Drawings can be attached by email — we price off the documents, not a guess.